  • MFR SKU: K-6933
  • ITEM #: 12643745
  • 0 Reviews / 0 Questions
$92.95
Stock Status: SHIPS SOON(reserve your unit today)

ITEM #: 12643745
Nitrate is the most completely o x idized form of nitrogen. It is formed during the final stages of biological decomposition, either in wastewater treatment facilities or in natural water supplies. Low-level nitrate concentrations may be present in natural waters. However, a Ma x imum Contaminant Level of 10 ppm nitrate-nitrogen has been established for drinking water by the USEPA.
The Cadmium Reduction Method
References: ASTM D 3867-09, Nitrate-Nitrite in Water, Test Method B. APHA...
ITEM #: 12643745
Nitrate is the most completely o x idized form of nitrogen. It is formed during the final stages of biological decomposition, either in wastewater treatment facilities or in natural water supplies. Low-level nitrate concentrations may be present in natural waters. However, a Ma x imum Contaminant Level of 10 ppm nitrate-nitrogen has been established for drinking water by the USEPA.
The Cadmium Reduction Method
References: ASTM D 3867-09, Nitrate-Nitrite in Water, Test Method B. APHA Standard Methods, 23rd ed, Method 4500-NO3-E-2016. USEPA Methods for Chemical Analysis of Water and Wastes, Method 353.3 (1983).
Nitrate is reduced to nitrite using cadmium as the reducing agent. The resulting nitrite concentration is then determined colorimetrically. This method is applicable to drinking and surface waters, as well as domestic and industrial wastes. Nitrite will interfere with this test. Results are e x pressed as ppm (mg/L) NO 3 -N or NO 3 .
Range: 0-50.0 ppm as NO 3
Method: Cadmium Reduction
Kit comes in a cardboard bo x and contains everything needed to perform 30 tests (e x cept distilled water): thirty ampoules, thirty cadmium foil packs, 25 mL sample cup, reaction tube with lid, 3.0 mL syringe, ampoule blank, and instructions.
Vacu-vials Kits require the use of the V-2000 Photometer or a spectrophotometer capable of accepting a 13 mm diameter round cell. Instrument sold separately.
WARNING! This product can e x pose you to chemicals including cadmium, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to .
Nitrate Vacu-vials Kit (Recommended Alternative to Hach Part 2511025)
This listing is for Each
Read More >>

Chemetrics - K-6933 - Nitrate Vacu-vials Kit (Recommended Alternative to Hach Part 2511025)

  • Item #: 12643745
  • MFR SKU: K-6933

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items