Other products by Cooper Bussmann / Eaton Electric

Cooper Bussmann / Eaton Electric - FRN-R-125 - Eaton Bussmann series FRN-R fuse, 125 A, Dual, Class RK5, Non-indicating, Blade end x blade end, 10 sec at 500%, 20 kAIC at 125 Vdc, 200 kAIC at 250 V, Standard, 250 V, 125 Vdc

  • MFR SKU: FRN-R-125
  • ITEM #: 4857384
  • 0 Reviews / 0 Questions
Lists At: $174.53 You Save: $105.58
60.49 % OFF
$68.95
Stock Status: In Stock

ITEM #: 4857384
These 250VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. UL Class RK5 fuses provide moderate current...
ITEM #: 4857384
These 250VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.
This listing is for each.
Read More >>

Cooper Bussmann / Eaton Electric - FRN-R-125 - Eaton Bussmann series FRN-R fuse, 125 A, Dual, Class RK5, Non-indicating, Blade end x blade end, 10 sec at 500%, 20 kAIC at 125 Vdc, 200 kAIC at 250 V, Standard, 250 V, 125 Vdc

  • Item #: 4857384
  • MFR SKU: FRN-R-125
  • Mounting: Blade
  • Amps: 125
  • Volts DC: 125
  • Opening: Time-Delay, Dual-Element, Slow-Blow
  • Class: RK5
  • Volts AC: 250
  • Interrupt Rating AC: 200kA
  • Interrupt Rating DC: 20kA

There are no questions about this product yet. Be the first to ask a question.