Cooper Bussmann / Eaton Electric - FRS-R-200 - Eaton Bussmann series FRS-R fuse, 200 A, Dual, Class RK5, Non-indicating, Blade end x blade end, 10 sec at 500%, 20 kAIC at 300 Vdc, 200 kAIC at 600 V, Standard, 600 V, 300 Vdc

  • MFR SKU: FRS-R-200
  • ITEM #: 4857397
  • 0 Reviews / 0 Questions
Lists At: $289.42 You Save: $185.47
64.08 % OFF
$103.95
Stock Status: In Stock

ITEM #: 4857397
These 600VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. UL Class RK5 fuses provide moderate current...
ITEM #: 4857397
These 600VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.
This listing is for each.
Read More >>

Cooper Bussmann / Eaton Electric - FRS-R-200 - Eaton Bussmann series FRS-R fuse, 200 A, Dual, Class RK5, Non-indicating, Blade end x blade end, 10 sec at 500%, 20 kAIC at 300 Vdc, 200 kAIC at 600 V, Standard, 600 V, 300 Vdc

  • Item #: 4857397
  • MFR SKU: FRS-R-200
  • Brand Eaton Bussmann series
  • Sub Brand Bussmann Series
  • Country of Origin Mexico
  • Made in USA No
  • Amperage Rating 200 A
  • Application Ind Facilities & Factories - Facility: Safety and Security Systems
  • Connection Blade end x blade end
  • Interrupt Rating 20 kAIC at 300 Vdc|200 kAIC at 600 Vac
  • Response Time 10 S at 500%
  • Special Features Renewable
  • Standard CE Marked
  • Item Type Fuse
  • Size 1.61 In Diameter X 9.63 In Length
  • Voltage Rating 600 Vac, 300 Vdc