Image is an illustration, may not reflect the exact product sold.


Other products by Cooper Bussmann / Eaton Electric

Cooper Bussmann / Eaton Electric - NOS-150 - Eaton Bussmann series NOS fuse, Supplemental one-time fuse, Non current limiting, Light duty circuit locations, 150 A, Class H, Non-indicating, Blade end x blade end, 10 kAIC at 600 Vac, Standard, 1, 600 V

  • MFR SKU: NOS-150
  • ITEM #: 4854255
  • 0 Reviews / 0 Questions
Lists At: $388.95 You Save: $12.06
3.10 % OFF
$376.89
Stock Status: SHIPS SOON (reserve your unit today)
Average lead time for this brand: 1-2 weeks. Specific products may vary.

ITEM #: 4854255
Fast-acting, nonindicating UL Class H and K5 fuses are for general purpose use in existing installations that require a high-sensitivity, fast-blow fuse. These fuses are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges, so they open within seconds of being exposed to overloads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Class H fuses are rated from...
ITEM #: 4854255
Fast-acting, nonindicating UL Class H and K5 fuses are for general purpose use in existing installations that require a high-sensitivity, fast-blow fuse. These fuses are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges, so they open within seconds of being exposed to overloads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover. Class H fuses are rated from 65A to 600A with an interrupting rating (IR) of 10kA for low-interrupt applications. Class K5 fuses are rated up to 60A with an interrupting rating (IR) of 50kA for higher interrupt applications and are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent. They're not labeled as current-limiting since they don't have a rejection feature. UL Class H and K5 fuses are used as replacement fuses for overcurrent protection in older HVAC installations. These fuses are dimensionally the same, so they can be interchanged to change from a current-limiting system using Class K fuses to a noncurrent-limiting system using Class H fuses. Class H fuses are used in low-interrupt applications while Class K fuses have a higher interrupting rating.
This listing is for each.
Read More >>

Cooper Bussmann / Eaton Electric - NOS-150 - Eaton Bussmann series NOS fuse, Supplemental one-time fuse, Non current limiting, Light duty circuit locations, 150 A, Class H, Non-indicating, Blade end x blade end, 10 kAIC at 600 Vac, Standard, 1, 600 V

  • Item #: 4854255
  • MFR SKU: NOS-150

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items