Image is an illustration, may not reflect the exact product sold.


Other products by Cytiva

Cytiva - 28918007 - PD MiniTrap G-25Item must be purchased in units of 1

  • MFR SKU: 28918007
  • ITEM #: 3527771
  • 0 Reviews / 0 Questions
Lists At: $568.29 You Save: $10.89
1.92 % OFF
$557.40
Stock Status: In Stock

ITEM #: 3527771
PD Mini. Trap G-25 columns are prepacked, single-use gravity columns for desalting, buffer exchange, and sample cleanup.
  • Flexible protocols with the ability to use gravity flow or centrifugation.
  • Convenient desalting and buffer exchange of sample volumes of 0.1 mL to 0.5 mL for gravity and 0.2 mL to 0.5 mL with centrifugation.
  • Replaces dialysis for desalting protein, which saves time and reduces labor.
  • Filled with Sephadex G-25 Medium resin.
Column for...
ITEM #: 3527771
PD Mini. Trap G-25 columns are prepacked, single-use gravity columns for desalting, buffer exchange, and sample cleanup.
  • Flexible protocols with the ability to use gravity flow or centrifugation.
  • Convenient desalting and buffer exchange of sample volumes of 0.1 mL to 0.5 mL for gravity and 0.2 mL to 0.5 mL with centrifugation.
  • Replaces dialysis for desalting protein, which saves time and reduces labor.
  • Filled with Sephadex G-25 Medium resin.
Column for desalting and buffer exchange of proteins

PD Mini. Trap G-25 is designed for convenient desalting of biological samples. For increased flexibility, the protein desalting column can be used with either gravity or centrifugation.
When using the gravity protocol, clean-up of the sample is simple. One or several columns can be connected in parallel, and a purification system is not needed. With the centrifugation protocol, the samples are run in parallel in a standard eluted sample will have minimal dilution.
Four adapters are included in each product pack. The adapters simplify centrifugation of these protein desalting columns.
The exclusion limit is approximately M r 5000. This ensures group separation of proteins/peptides larger than M r 5000 from smaller molecules.Successful use in published research

PD Mini. Trap G-25 are used in a variety of research applications, including:
  • Buffer exchange during in vitro assembly of catalase
  • Removal of DTT during study of thiosulfate transfer in Metallosphaera cuprina
  • Imidazole removal during study of disparate ligand binding sites in the human P2Y1 receptor
Other products for buffer exchange or desalting

  • PD Spin. Trap G-25 spin column for small sample quantities using a benchtop centrifuge - up to 180 µL sample volume
  • PD Midi. Trap G-25 gravity column for sample volumes up to 1 mL
  • PD-10 Desalting gravity column for sample volumes up to 2.5 mL
  • Hi. Trap Desalting columns for sample volumes up to 1.5 mL. For use with a syringe, a peristaltic pump, or a chromatography system
  • Hi. Prep Desalting column for sample volumes up to 15 mL. For use with a laboratory pump or a chromatography system
  • PD Multi. Trap G-25 for high-throughput desalting and buffer exchange of multiple samples
  • This resin is available as bulk resin

This listing is for package of 50 columns.
Read More >>

Cytiva - 28918007 - PD MiniTrap G-25Item must be purchased in units of 1

  • Item #: 3527771
  • MFR SKU: 28918007
  • Bed Volume: 2.1 ml
  • Certificate of Analysis: Yes
  • Sample Volume: 0.1 to 0.5 ml (Gravity), 0.2 to 0.5 ml (Spin)
  • Complete Packsize: 1 Piece
  • Storage Conditions: 4 to 30°C, 0.15% Kathon CG/ICP Biocide
  • Wetted Part: No
  • BioProcess resin: Yes
  • Matrix: Cross-linked dextran
  • Particle size distribution, wet: 38-235 µm
  • Partical Size Dry: >50 µm
  • PH stability, operational: 2-131)
  • PH stability, CIP: 2-132)
  • Pressure/Flow Specification: >100 cm/h, pressure drop cm H2O/bed height=2, bed height 30 cm, 2.6 cm i.d.
  • Fractionation range [Mr], Globular proteins: 1 × 103-5 × 103
  • Fractionation [Mr] Dextrans: 1 x 102-1 x 102
  • Exclusion Limit [Mr] [Globular Proteins]: > 5 × 103
  • Exclusion Limit: Mr 5000
  • Storage: 4 to 30°C, dry resins. Used resins 4 to 8 °C in 20% Ethanol or 0.01 M NaOH
  • Chemical Stability: All commonly used buffers
  • Column i.d.: 9.7 mm
  • Material [Column Hardware]: Polypropylene (PP)
  • Material [Bed Support]: Polyethylene (PE)

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items