ITEM #: 24051061

VacuShield & VacuShield PF vacuum filtration devices, a Pall Life Sciences product, are innovative bottle-top filters for fast vacuum filtration of 100 mL to 5 L of aqueous solutions.

Replace current vacuum filter systems
Simplify workflow
Maximize filtration
Filter faster. Supor membrane provides high flow rates.
No need to constantly refill upper fluid reservoir.
Draws directly from the mixing reservoir.
Eliminates the possibility...
ITEM #: 24051061

VacuShield & VacuShield PF vacuum filtration devices, a Pall Life Sciences product, are innovative bottle-top filters for fast vacuum filtration of 100 mL to 5 L of aqueous solutions.

Replace current vacuum filter systems
Simplify workflow
Maximize filtration
Filter faster. Supor membrane provides high flow rates.
No need to constantly refill upper fluid reservoir.
Draws directly from the mixing reservoir.
Eliminates the possibility of contamination from transfer steps. Filters directly into the desired container.
Match filter to sample volume by choosing from two sizes.
Available built-in prefilter increases throughput of particulate-laden solutions such as serum-containing media.
Environmentally-friendly with minimal plastic waste.
Patented small design accepts a variety of collection vessels and reduces storage space and waste.
TA version available with tubing attached to each device for maximum convenience.
Gamma irradiated, eliminates potential contamination by EtO residuals Materials of Construction


Filter Media: Supor[hydrophilic polyethersulfone (PES)] membrane
Housing: Modified acrylic
Membrane Support Material: Polyester
Sinker Material: Glass-filled polyurethane elastomer
Inlet Tubing: Polyvinyl chloride (PVC) medical-grade tubing
Gasket Seal Material: PolyethylenePore Size


0.1, 0.2, 0.45, and 0.8/0.2 μmEffective Filtration Area


VacuCap 60 Devices: 30 cm 2
VacuCap 90 Devices: 60 cm 2 Typical Throughput


(RPMI + 10% newborn calf serum)

VacuCap 60 Devices, 0.2 μm: 1 L
VacuCap 90 Devices, 0.2 μm: 5 L
(RPMI + 10% calf serum)

VacuCap 60 PF Devices: 500 mL
VacuCap 90 PF Devices: 1 LCollection Vessel


VacuCap 60 Devices: Can be used on receptacles with openings ranging from 2 - 5 cm (0.8 - 1.9 in.)
VacuCap 90 Devices: Can be used on receptacles with openings ranging from 2 - 6.5 cm (0.8 - 2.5 in.)
Warning: Collection vessels should be vacuum rated. Implosion may result.Typical Hold-Up Volume


VacuCap 60 Devices: 1.2 mL
VacuCap 90 Devices: 3.2 mLMaximum Operating Temperature


55°C (131°F)Recommended Vacuum


38.1 cm Hg (15 in. Hg)
VacuCap 60 Devices

0.1 µm: 50
0.2 µm: 200
0.45 µm: 280
PF: 200
VacuCap 90 Devices

0.1 µm: 100
0.2 µm: 400
0.45 µm: 560
PF: 400Endotoxin Level


< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) testBiological Safety


Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo Sterilization


Sterilized by gamma irradiation and individually packagedApplication


Excellent device for cell culture media preparation
PF version is useful for sterilization of hard-to-filter solutions
Reduce mycopalsma with the 0.1 µm pore size
View our video on vacuum filtration made easyMaterials of Construction

Filter Media: Supor[hydrophilic polyethersulfone (PES)] membrane
Housing: Modified acrylic
Membrane Support Material: Polyester
Sinker Material: Glass-filled polyurethane elastomer
Inlet Tubing: Polyvinyl chloride (PVC) medical-grade tubing
Gasket Seal Material: PolyethylenePore Size

0.1, 0.2, 0.45, and 0.8/0.2 μmEffective Filtration Area

VacuCap 60 Devices: 30 cm 2
VacuCap 90 Devices: 60 cm 2 Typical Throughput

(RPMI + 10% newborn calf serum)
VacuCap 60 Devices, 0.2 μm: 1 L
VacuCap 90 Devices, 0.2 μm: 5 L
(RPMI + 10% calf serum)
VacuCap 60 PF Devices: 500 mL
VacuCap 90 PF Devices: 1 LCollection Vessel

VacuCap 60 Devices: Can be used on receptacles with openings ranging from 2 - 5 cm (0.8 - 1.9 in.)
VacuCap 90 Devices: Can be used on receptacles with openings ranging from 2 - 6.5 cm (0.8 - 2.5 in.)
Warning: Collection vessels should be vacuum rated. Implosion may result.Typical Hold-Up Volume

VacuCap 60 Devices: 1.2 mL
VacuCap 90 Devices: 3.2 mL
Maximum Operating Temperature55°C (131°F)Recommended Vacuum

38.1 cm Hg (15 in. Hg)Endotoxin Level

< 0.25 EU/mL using Limulus Amoebocyte Lysate (LAL) testBiological Safety

Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo Sterilization

Sterilized by gamma irradiation and individually packagedApplication

Excellent device for cell culture media preparation
PF version is useful for sterilization of hard-to-filter solutions
Reduce mycopalsma with the 0.1 µm pore size
Read More >>

Cytiva - 4624 - VacuCap 0.45 &micro;m, 90 mm, gamma-irradiated (10/pkg)Item must be purchased in units of 1

  • Item #: 24051061
  • MFR SKU: 4624
  • Connections: 3 over 4 hose barb inner taper in
  • Effective Filtration Area: 60 cm²
  • Media/Membrane: Supor Hydrophilicpolyethersulfone
  • Pore Size (Removal Rating): 0.45 µm
  • Quantity: 10
  • Size (Metric): 90 mm
  • Sterile: Sterile
  • Pore size: 0.45 µm