Image is an illustration, may not reflect the exact product sold.


Other products by Edwards Signaling

Edwards Signaling - INT-05-024 - INT-05-024, SAFETY EXPANSION RE, ( Each )

  • MFR SKU: INT-05-024
  • ITEM #: 11898731
  • 0 Reviews / 0 Questions
$797.85
Stock Status: SHIPS SOON(reserve your unit today)
Average lead time for this brand: 1-2 weeks. Specific products may vary.

ITEM #: 11898731
INT-05-024 - Edwards Signaling INT-05-024, SAFETY EXPANSION RE
The INT-05-024 or INT-05-120 Expansion Safety Relay is intended for use as a part of a safety circuit. It provides three additional safe output contacts when used with the INT-03 Safety Monitoring Relay or INT-04 Emergency-Stop Safety Relay.
The INT-05 uses positive-guided relays along with feedback contact to the INT-03 or INT-04 safety relay to prevent machine start-up in the event of a component failure.
Voltage...
ITEM #: 11898731
INT-05-024 - Edwards Signaling INT-05-024, SAFETY EXPANSION RE
The INT-05-024 or INT-05-120 Expansion Safety Relay is intended for use as a part of a safety circuit. It provides three additional safe output contacts when used with the INT-03 Safety Monitoring Relay or INT-04 Emergency-Stop Safety Relay.
The INT-05 uses positive-guided relays along with feedback contact to the INT-03 or INT-04 safety relay to prevent machine start-up in the event of a component failure.
Voltage to the INT-05 is switched through the contacts of the INT-03 or INT-04. If a component failure occurs, the feedback loop to the INT-03 or INT-04 prevents machine restart.
Applications
  • Adds 3 safe outputs when used with Sentrol Safety Relays INT-03 and INT-04
  • Maintains safety circuit integrity by providing feedback to INT-03 or INT-04 to inhibit machine restart in case of component failure
  • Electrical isolation between input and output
  • Switches AC or DC loads
  • DIN Rail or panel mount
  • LEDs indicate relay status
Read More >>

Edwards Signaling - INT-05-024 - INT-05-024, SAFETY EXPANSION RE, ( Each )

  • Item #: 11898731
  • MFR SKU: INT-05-024
  • Specifications
  • Control Inputs (X1, X2 & Y1, Y2 terminals)
  • Open-circuit voltage = 24VDC
  • Closed-circuit current = 24mA
  • resistance = 30 Ohms
  • Simultaneity = 500 ms typical
  • Safe Outputs (A, B/C, D/E, F terminals)
  • Voltage = 230 VAC/60VDC
  • Current = 4A (resistive)
  • Response time = ON: < 40 ms, OFF: < 30 ms
  • Fuse = 4A, 250V, 5 x 20 mm, F/T
  • AUX. Signaling Outputs (F1, F2 terminals)
  • Voltage = 120 VAC/30VDC
  • Current = 1A (resistive)
  • -----------------------------------------------------------------------------------------------------------------------
  • Note: Transient protection is required across the load when switching an inductive load.
  • Operation
  • A. With voltage applied to control inputs via INT-03 or INT-04 output contacts, relay energizes
  • B. With control voltage removed, relay de-energizes
  • C. If an internal failure has occurred, feedback loop will not close thereby disabling INT-03 or
  • INT-04

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items