Hach - 5410010 - SP510 Hardness Analyzer (10 mg/L trip point)

  • MFR SKU: 5410010
  • ITEM #: 10446967
  • 0 Reviews / 0 Questions
$4,362.46
  • Saw It For Less?
Stock Status: SHIPS SOON(reserve your unit today)
Average lead time for this brand: 1-2 weeks. Specific products may vary.

ITEM #: 10446967
Analyzer immediately signals hardness breakthrough to activate regeneration. The SP510 Analyzer makes your water softening system more efficient and less costly. It's reliable , simple and accurate- with automated calibration and continuous monitoring.
  • Continuous Hardness Detection
  • Simple to Read and Use
  • Rugged , lightweight , and self-contained
  • Making Water Softening Systems Cost-efficient
  • Low Maintenance Requirements

Hach - 5410010 - SP510 Hardness Analyzer (10 mg/L trip point)

  • Item #: 10446967
  • MFR SKU: 5410010
  • Continuous Hardness Detection
  • By performing an analysis every two minutes , the SP 510 monitor can establish an automatic or semi-automatic system for water softener regeneration in a variety of commercial or industrial applications. Simple to Read and Use
  • The SP 510 monitor detects hardness breakthrough when the capacity of a water softener is exhausted , immediately signaling the need for regeneration. Alarm points are 0.3 , 1 , 2 , 5 , 10 , 20 , 50 , and 100 ppm (expressed as mg/L of CaCO3) and are selected by using the appropriate model. LED indicators show a simple HARD or SOFT sample status. Use the monitor's built-in alarm relay to actuate an external annunciator. Rugged , lightweight , and self-contained
  • The case of the SP 510 monitor is made of ABS plastic which is lightweight , corrosion-resistant , and shatterproof. This sealed case is IP62-rated and has a hinged door that for easy access to internal components. All electronic circuits are isolated from the hydraulics compartment. A large window allows inspection of both LED indicators and reagent supplies at a glance. Wall-mounting is easy with built-in brackets. The instrument is rated for 115/220 Vac , 50/60 Hz operation , with a switch for voltage selection. Making Water Softening Systems Cost-efficient
  • The traditional method of determining softener regeneration cycles is based on calculation of the water volume that can pass through a softener before its capacity is exhausted. Many variables (temperature , flow rate , and condition of the exchange resin) can affect the accuracy of these calculations. A substantial safety margin is also generally included , which can result in waste of time and brine used for regeneration. The softener is regenerated only when needed , based on accurate chemical analysis rather than estimated volume. Low Maintenance Requirements
  • The SP 510 monitor is designed for continuous , unattended use. It is virtually maintenance-free , requiring only about 15 minutes every two months to replenish and standardize the reagents. Tubing in the pump system should be replaced at six-month intervals. Spare pump tubing is supplied with the monitor. What's included?
  • Accuracy: \xc2\xb125% of set point value
  • Alarm: 2 consectutive cycles above set point activate alarm. 1 cycle below set point cancels alarm.
  • Alarm points: 10 mg/L of CaCO\xe2\x82\x83 trip point
  • Certifications: NRTL certified to UL and CSA standards , and CE approved
  • Cycle Time: 2 average
  • Dimensions (H x W x D): 419 mm x 318 mm x 178 mm
  • Fitting Type: Inlet: \xc2\xbc-in. OD tube quick-disconnect fitting
  • Outlet: \xc2\xbd-in. ID flexible hose
  • Maintenance Interval: Standardise and replenish reagents every 2 months using EDTA or high-level sample
  • Replace pump tubes every 6 months
  • Material Enclosures: ABS plastic , large plastic windows to view alarm and reagents level
  • Measurement Method: Colorimetric
  • Operating Humidity: 5 - 95% , non-condensing
  • Operating Temperature Range: 5 - 40 \xc2\xb0C
  • Outputs: 1 SPDT relay
  • Power Requirements (Hz): 50/60 Hz
  • Power Requirements (Voltage): 115/230 V AC
  • Reagent Consumption: 500 mL each indicator and buffer every two months
  • Reagent Requirements: each of indicator and buffer. Replenish every two months for continuous operation.
  • Repeatability: \xc2\xb1 10 % of set point value in 0.3 - 2 mg/L ranges
  • \xc2\xb1 4 % of set point value in 5 - 100 mg/L ranges
  • Sample Flow Rate: 50 - 500 mL/min
  • Sample Pressure: 0.07 - 0.34 bar (0.10 bar is optimum)
  • Sample conditioning: 0.10 - 5.17 bar
  • Storage Conditions: -40 - 60 \xc2\xb0C
  • Warranty: 12 months
  • Weight: 11.3 kg