Simplify testing in demanding industrial and wastewater applications Identifies stable readings to ensure accurate analysis Displays measurements more clearly on large, color touch screen Locks in measurements and logs up to 2000 data points Easily exports data via a USB port The TL23 series benchtop turbidimeters simplify the measurement of high range turbidity applications with an easy-to-use color touch screen and intuitive user interface. Features include self-diagnostics for quality assurance,...
ITEM #: 10447434
Simplify testing in demanding industrial and wastewater applications Identifies stable readings to ensure accurate analysis Displays measurements more clearly on large, color touch screen Locks in measurements and logs up to 2000 data points Easily exports data via a USB port The TL23 series benchtop turbidimeters simplify the measurement of high range turbidity applications with an easy-to-use color touch screen and intuitive user interface. Features include self-diagnostics for quality assurance, single-point calibration for measurements under 40 NTU/FNU, and sample identification for traceability. Stable readings and accurate analysis are ensured by capturing turbidity reading once the turbidimeter detects sample stability. No need for repeat measurements. USEPA filter assembly, six 1-inch sample cells (30 mL) with caps, Gelex secondary turbidity standardization kit, StablCal calibration kit, silicone oil, oiling cloth, power supply, power cord, and dust cover. This listing is for Each.
Read More >>

Hach - LPV444.99.00120 - Hach TL2310 LED Turbidimeter, ISO, 0 to 1000 NTU

  • Item #: 10447434
  • MFR SKU: LPV444.99.00120
  • Improved and intuitive design
  • The TL23 Series\xe2\x80\x99 large full color touch screen display and intuitive user interface accelerate setup , calibration and measurement. An easy interface and guided procedures give you confidence in your results. A smart device for more reliable measurements
  • The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements. Easy to use. Easy to Be Right
  • The TL23 Series provides everything you need at your fingertips. What's included?
  • TL2310 Turbidimeter , silicone oil , oiling cloth , 1-inch sample cells (30 mL) with caps (6x) , Gelex secondary turbidity standardization kit , Stablcal calibration kit , power supply , power cord , dust cover
  • Accuracy: \xc2\xb12% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU
  • Air Purge: Dry nitrogen or instrument grade air (ANSI MC 11.1 , 1975)
  • 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
  • Hose barb connection for 1/8-inch tubing
  • Certifications: CE , KC , RCM
  • Communication: USB
  • Compliance: ISO
  • Data Logging: 2000 total logs , includes reading log , verification log and calibration log
  • Dimensions (H x W x D): 153 mm x 395 mm x 305 mm
  • Display: 17.8 mm (7 in.) color touch screen
  • Interface: 2 USB-A ports for USB flash drive , external printer , keyboard and barcode scanner
  • Light Source: Light-emitting diode (LED) at 860 \xc2\xb1 30 nm
  • Measurement Method: Nephelometric
  • Model: TL2310 ISO
  • Operating Temperature Range: 0 - 40 \xc2\xb0C
  • Power Requirements (Amps): 3.4 A
  • Power Requirements (Hz): 50/60 Hz
  • Power Requirements (Voltage): 100 - 240 VAC
  • Range: 0 - 1000 NTU
  • NTU/FNU: 0 - 1000
  • Reading Modes: Single , continuous , Rapidly Settling Turbidity\xe2\x84\xa2 , signal averaging on or off
  • Regulatory: Meets ISO 7027 , DIN EN 27027 , DIN 38404 and NFT 9033
  • Repeatability: \xc2\xb11% of reading or 0.01 FNU/NTU , whichever is greater (under reference conditions)
  • Response Time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
  • Sample Cell Compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
  • Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
  • Sample Requirements: 25 mm sample cell: 20 mL minimum
  • 0 to 70 \xc2\xb0C (32 to 158 \xc2\xb0F)
  • Source Lamp: LED
  • Stabilization Time: Immediately
  • Storage Conditions: -20 to 60 \xc2\xb0C
  • Units: FNU and NTU
  • Warranty: 12 months
  • Weight: 3.0 kg
  • What's included?: TL2310 Turbidimeter , silicone oil , oiling cloth , 1-inch sample cells (30 mL) with caps (6x) , Gelex secondary turbidity standardization kit , Stablcal calibration kit , power supply , power cord , dust cover
  • TL2310 Turbidimeter , silicone oil , oiling cloth , 1-inch sample cells (30 mL) with caps (6x) , Gelex secondary turbidity standardization kit , Stablcal calibration kit , power supply , power cord , dust cover