Hach - LPV444.99.00310 - Hach TL2350 Tungesten Lamp Turbidimeter, EPA, 0 to 10, 000 NTU

  • MFR SKU: LPV444.99.00310
  • ITEM #: 10447435
  • 0 Reviews / 0 Questions
$6,516.24
  • Saw It For Less?
Stock Status: SHIPS SOON (reserve your unit today)
Average lead time for this brand: 1-2 weeks. Specific products may vary.

ITEM #: 10447435
Simplify testing in demanding industrial and wastewater applications Identifies stable readings to ensure accurate analysis Displays measurements more clearly on large, color touch screen Locks in measurements and logs up to 2000 data points Easily exports data via a USB port The TL23 series benchtop turbidimeters simplify the measurement of high range turbidity applications with an easy-to-use color touch screen and intuitive user interface. Features include self-diagnostics for quality assurance,...
ITEM #: 10447435
Simplify testing in demanding industrial and wastewater applications Identifies stable readings to ensure accurate analysis Displays measurements more clearly on large, color touch screen Locks in measurements and logs up to 2000 data points Easily exports data via a USB port The TL23 series benchtop turbidimeters simplify the measurement of high range turbidity applications with an easy-to-use color touch screen and intuitive user interface. Features include self-diagnostics for quality assurance, single-point calibration for measurements under 40 NTU/FNU, and sample identification for traceability. Stable readings and accurate analysis are ensured by capturing turbidity reading once the turbidimeter detects sample stability. No need for repeat measurements. USEPA filter assembly, six 1-inch sample cells (30 mL) with caps, Gelex secondary turbidity standardization kit, StablCal calibration kit, silicone oil, oiling cloth, power supply, power cord, and dust cover. This listing is for Each.
Read More >>

Hach - LPV444.99.00310 - Hach TL2350 Tungesten Lamp Turbidimeter, EPA, 0 to 10, 000 NTU

  • Item #: 10447435
  • MFR SKU: LPV444.99.00310
  • Accuracy: Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU ±10 % of reading from 4000 - 10000 NTU
  • Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
  • Accuracy 3: Absorbance: ±0.01 Abs from 0 - 0.5 Abs at 455 nm, ±2% Abs from 0.5 - 1 Abs at 455 nm
  • Transmittance: 2% T from 10 - 100% T at 455 nm
  • Air Purge: Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
  • 0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max
  • Hose barb connection for 1/8-inch tubing
  • Certifications: CE, KC, RCM
  • Communication: USB
  • Compliance: EPA
  • Data Logging: 2000 total logs, includes reading log, verification log and calibration log
  • Dimensions (H x W x D): 153 mm x 395 mm x 305 mm
  • Display: 17.8 mm (7 in.) color touch screen
  • Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
  • Light Source: Tungsten filament lamp
  • Measurement Method: Nephelometric
  • Model: TL2350 EPA
  • Operating Temperature Range: 0 - 40 °C
  • Power Requirements (Amps): 3.4 A
  • Power Requirements (Hz): 50/60 Hz
  • Power Requirements (Voltage): 100 - 240 VAC
  • Range: 0 - 10000 NTU
  • NTU (Ratio on): 0 - 10000 auto decimal
  • NTU (Ratio off): 0 - 40
  • EBC (Ratio on): 0 - 2450 auto decimal
  • EBC (Ratio off): 0 - 9.8
  • Absorbance (auto range): 0 - 1.0
  • Transmittance (%): 1.0 - 100
  • Degree (mg /L): 1 - 100
  • Reading Modes: Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
  • Region: Global
  • Regulatory: Meets EPA Method 180.1
  • Repeatability: ±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
  • Response Time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
  • Sample Cell Compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps
  • Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.
  • Sample Requirements: 25 mm sample cell: 20 mL minimum
  • 0 to 70 °C (32 to 158 °F)
  • Source Lamp: Tungsten Lamp
  • Stabilization Time: Ratio on: 30 minutes after start-up
  • Ratio off: 60 minutes after start-up
  • Storage Conditions: -20 to 60 °C
  • Units: NTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L
  • Weight: 3.0 kg
  • What's included?: TL2350 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover
  • TL2350 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover