Image is an illustration, may not reflect the exact product sold.


Other products by Infinite Electronics

Infinite Electronics - 1101-640 - Data Surge Protector SPD ALPU Outdoor 10/100 Base-T Ethernet/PoE+ 110 Punch Down Block SASD, UL 497, Primary Protector

  • MFR SKU: 1101-640
  • ITEM #: 8301467
  • 0 Reviews / 0 Questions
Lists At: $440.99 You Save: $101.43
23.00 % OFF
$339.56
Stock Status: In Stock

ITEM #: 8301467
ELECTRICAL SERVICE: Ethernet. Signal Voltage ............................................................................................... 55 VDCTransfer rate .....................................................................................................CAT-5Configuration..................................................................................................... 2 pair. Input Connection ................................................... Screw-Term Block (24-16 AWG)Protection Modes.............................................................
ITEM #: 8301467
ELECTRICAL SERVICE: Ethernet. Signal Voltage ............................................................................................... 55 VDCTransfer rate .....................................................................................................CAT-5Configuration..................................................................................................... 2 pair. Input Connection ................................................... Screw-Term Block (24-16 AWG)Protection Modes.......................................................... Line to Line, Line to Ground. Maximum Continuous Operating Voltage .................................................. 90 VDCVDCService Voltage ............................................................................................. 55 VDCConfiguration........................................................................................... up to 4 wire. Input Connection .................................................. Screw-Term. Block (24-16 AWG)Protection Modes.......................................................... Line to Line, Line to Ground. Maximum Continuous Operating Voltage .................................................. 90 VDCReset Wire/LED Signal Wire. Service Voltage ............................................................................................. 55 VDCConfiguration............................................................................................. 1 wire (ea)Input Connection .................................................... Screw-Term Block (24-16AWG)Protection Mode............................................................ Line to Line, Line to Ground. Maximum Continuous Operating Voltage ................................................... 90VDC ELECTRICAL PERFORMANCE: 3Tested to IEEE/ANSI 10/1000ms Long Wave. Peak Current..............................................................................................150A peak. Voltage Protection Level ...............................................130Vpk @ 150A 10/1000ms. Tested to IEEE/ANSI 8/20ms Combination Wave. Peak Current............................................................................................1500A peak. Voltage Protection Level ...................................................152Vpk @ 1500A 8/20ms. Peak Power Dissipation ...............................................................................20, 000 Watts. Response Time (Max.)...............................................................................5 nanoseconds ENVIRONMENTAL: Operating Temperature:............................................................................-40C to +80CStorage Temperature: ...............................................................................-40C to +80CRelative Humidity:...........................................................................99%(non-condensing)MECHANICAL/INSTALLATION:Refer to Transtector Installation Instruction document 1200- 148 for further information regarding the installation of this dimensions: The suppressor is housed in a molded plastic enclosure that is 6.13 in long, 4.5 in wide and 2.5 in tall. Mounting data: The enclosure mounts with #6 data: The ALPU-ALVR surge suppressor is designed to accept (2) multiconductor cables with outside diameters of up to 0.375".The ALPU-ALVR surge suppressor is a high-speed, high-current solid state device designed to protect (1) 55 VDC Ethernet CAT-5 line, (1) 55 VDC LED Signal wire, (1) 55 VDC Reset Wire, and (1) 55 VDC pair. The ALPU-ALVR surge suppressor uses only silicon avalanche suppression diodes (SASD). It connects to the service in a pass through configuration. All input and output connections terminate at two "screw type" terminal blocks. Both the input and output harnesses pass into the suppressor housing via waterproof strain reliefs. The molded plastic enclosure is also waterproof and features integrated mounting holes that are concealed by the cover and integrated gasket as well as a "Membrane Vent" to release any build-up of pressure and moisture due to cable wicking and enclosure heating.
Read More >>

Infinite Electronics - 1101-640 - Data Surge Protector SPD ALPU Outdoor 10/100 Base-T Ethernet/PoE+ 110 Punch Down Block SASD, UL 497, Primary Protector

  • Item #: 8301467
  • MFR SKU: 1101-640
  • NULL

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items