Capacity: 2000VA / 1930W, Topology: Online double-conversion, Wave Form: Sine wave, Outlets: 8, Features:, 0.96 power factor, Zero transfer time from Line to Battery, Adjustable charging current up to 8A, Expandable runtime, Load segment control, 50/60Hz Frequency Converter Mode, Emergency Power Off (EPO), ECO and Advanced ECO Modes, . The UltimaPro RT was designed to protect and backup small and large-scale mission-critical equipment from power disturbances detrimental to workflow continuity. Double-conversion...
ITEM #: 24163094
Capacity: 2000VA / 1930W, Topology: Online double-conversion, Wave Form: Sine wave, Outlets: 8, Features:, 0.96 power factor, Zero transfer time from Line to Battery, Adjustable charging current up to 8A, Expandable runtime, Load segment control, 50/60Hz Frequency Converter Mode, Emergency Power Off (EPO), ECO and Advanced ECO Modes, . The UltimaPro RT was designed to protect and backup small and large-scale mission-critical equipment from power disturbances detrimental to workflow continuity. Double-conversion online topology with true sine wave output delivers seamless operation, reliability, and stability to stay powered through mains power failures while delivering the clean power for sensitive equipment. Advanced technology makes this a high-performing UPS the ideal solution within small spaces with maximum energy efficiency to cut down on energy costs and lower environmental impact, plus built-in battery connector allows battery expansion to increase battery runtime to minimize downtime even more. The rack mount form factor was designed to fit rack cabinets where space consideration is essential. Typical Applications Mid-size servers ATMs Lab equipment Networking devices Surveillance systems VoIP / PBX systems Security systems Gaming computers Slot machines Main Features (8) Battery-Backed Outlets with Surge Suppression These outlets keep critical electronics online during a temporary blackout, adjust minor voltage fluctuations, and offer protection from power surges and voltage spikes. If a blackout occurs or a power disruption beyond the tolerance range is detected, the UPS will switch over to battery power and supply these outlets with power. Connect mission-critical electronics to these outlets. True Double-Conversion Online Topology The main supply is fed directly into the UPS and charges batteries within the UPS. The battery power is then converted back to the main power to feed the protected equipment. Due to these two conversions, this UPS type is often known as a Double-Conversion UPS. Zero Transfer Time True online double-conversion topology for zero transfer time from Line Mode to Battery Mode in case of a power disturbance prevents malfunction of mission-critical equipment. Pure Sine Wave Output Best waveform for sensitive electronics. Benefits include: Smoother waveform Best for sensitive equipment Higher quality than a modified sine wave Maintains voltage at a safe level Motors run at their intended speed and with less heat Equipment runs with less noise IT equipment lasts longer Low harmonic distortion Overload Protection Protects the UPS from an overload. If the circuit breaker trips, unplug a few electronics before resetting the circuit breaker and turning your unit back on. 0.96 Power Factor A high power factor rating offers efficient loading of the power supply. It maximizes energy efficiency to cut down on energy cost and energy loss by reducing the load on transformers and distribution equipment. Emergency Power Off (EPO) Tab Instantly shut off the UPS and prevent the UPS from supplying power in the event of an emergency. Load Segment Control Control grouped outlets allows better management of battery power by prioritizing mission-critical devices by manual or pre-setting. This allows mission-critical devices to have longer backup time than non-mission-critical devices. Expandable Battery Runtime Add up to 3 external battery banks to extend the battery runtime of your UPS. 2A to 8A Adjustable Battery Charger Select between 2A to 8A battery charging current for faster battery recharge time depending on the number of external battery modules connected to the UPS. This is especially useful if located in an area with frequent power disturbances that would cause the UPS to run on Battery Mode frequently. Hot Swappable Batteries Replace batteries without shutting off the UPS to avoid downtime. Power Management Software Monitor and control the UPS from your computer with the included user-friendly software to automate computer shutdown, monitor battery levels, set UPS parameters, receive alerts of abnormalities, and more. 50/60Hz Frequency Converter Mode Select 50Hz or 60Hz output frequency best suited for connected equipment. It is especially helpful when used to help regulate the speed of motorized equipment to match the frequency. NOTE: If input frequency is 60Hz, setting the UPS output frequency to 50Hz will derate the UPS capacity by 40%. Rack / Tower Convertible Install the UPS in vertically or horizontally. EMI / RFI Filter EMI / RFI filter suppresses electromagnetic noise and radio frequency interference transmitted from AC power. ECO and Advanced ECO Modes Efficiency Corrective Optimizer (ECO) improves energy consumption by changing how power flows through the UPS. ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are still active in this mode. Advanced ECO Mode: Improves energy efficiency of the UPS by setting the UPS to "standby." Input power will bypass voltage to output when the input voltage is within the acceptable range. Power factor correction and the inverter are not active in this mode. Cold Start Capable Turn on the UPS even without utility power as long as there is sufficient battery power. Auto-Restart During AC Recovery Once power returns to normal and the battery levels are sufficient, the UPS will automatically restart. Off-Mode Charging The UPS continues charging the internal batteries when powered off as long as the unit is plugged into an AC mains wall socket. LCD Screen See real-time status information of your UPS power conditions including the voltages, battery level, fault detected, and more. Enable / Disable Audible Alarm Enable or disable the audible alert for your unit. To enable or disable the audible alarm, turn the LCD screen on first then press the button twice quickly. The UPS will beep once the alarm is enabled. The default setting for the audible alarm is enabled. If the alarm is disabled, no audible alert will be made when the UPS reaches a low battery state. Optional Accessories (Not Included) Network Management Card - For remote power monitoring. See model number #SNMP-2 for compatibility with this UPS series. Rail Kit - For installation to rack cabinets. See model # ULT-RMKIT123 for the compatible rail kit to this UPS. Add-On External Battery Banks - Extend the battery runtime in the event of an extended power outage. See model # ULT-P2KRTKBB for compatibility with this UPS. Warranty (US & Canada) 2-year equipment warranty, 2-year battery warranty, and 2-year $25, 000 connected equipment warranty with product registration . See the Warranty page for additional information. WARNING: The batteries, battery posts, terminals, and related accessories can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects, or other reproductive harm. Wash hands after handling. For more information, go to www.p65warnings.ca.gov .
Read More >>

Maruson Technology - ULT-P2KRT - 2000VA Online Rack Mount Uninterruptible Power Supply

  • Item #: 24163094
  • MFR SKU: ULT-P2KRT
  • Model: ULT-P2KRT Capacity: 2000VA / 1930W Topology: Online double-conversion Voltage: 100 / 110 / 115 / 120 / 127Vac Voltage Range: 55 - 150Vac +/- 5% at 50% load80 - 150Vac +/- 5% at 100% load Frequency: 40 - 70Hz Inlet: NEMA 5-20P; 20A T-blade plug Output Voltage: 100 / 110 / 115 / 120 / 127Vac Frequency Range (on Battery): 50 / 60
  • Hz +/- 1% Current Crest Ratio: 3:1 (max) Harmonic Distortion: