Image is an illustration, may not reflect the exact product sold.


Other products by Schneider Electric

Schneider Electric - ATV312HD11N4 - Schneider Electric / Square D ATV312HD11N4 Altivar 31 Variable Frequency AC Speed Drive; 3 Phase, 480 Volts, 15 HP

  • MFR SKU: ATV312HD11N4
  • ITEM #: 23190281
  • 0 Reviews / 0 Questions
$2,654.30
  • Saw It For Less?
Stock Status: SHIPS SOON(reserve your unit today)

ITEM #: 23190281
ATV312HD11N4 SQD AC DRIVE 15 HP 480V 3 PHASE
Schneider Electric, AC DRIVE15 HP 480V 3 PHASE, 11kW, 3 phases, 3-Phase, 3-Phase, 380/500Vac, Altivar 312, Altivar 312, IP20, Modbus-CANopen, Modbus-CANopen, simple machine, UL Listed, CSA Certified, CE Marked, variable speed drive

Schneider Electric - ATV312HD11N4 - Schneider Electric / Square D ATV312HD11N4 Altivar 31 Variable Frequency AC Speed Drive; 3 Phase, 480 Volts, 15 HP

  • Item #: 23190281
  • MFR SKU: ATV312HD11N4
  • Product Specification
  • Application 11 KW, 15 HP, ASYNCHRONOUS MOTORS, SIMPLE MACHINE
  • Brand ALTIVAR 312
  • Display DRIVE VOLTAGE 1 LED RED)-CANOPEN BUS STATUS FOUR 7-SEGMENT DISPLAY UNITS
  • Enclosure IP20
  • Environmental Conditions -10-50 AC WITHOUT WITH PROTECTIVE COVER ON TOP OF THE DRIVE)--10-60 AC WITH DERATING FACTOR WITHOUT PROTECTIVE COVER ON TOP OF THE DRIVE)
  • 00785901823469
  • Height 12.0000
  • Height Unit IN
  • Input 3-PHASE
  • Item Status A
  • Length 16.0000
  • Length UOM IN
  • Output 3-PHASE
  • Phase 3 PHASES
  • Ships Freight No
  • Ships Ground. Eligible for expedited shipping Yes
  • Size 192 MM, 245 MM, 329.5 MM
  • Special Features AL1, AL2, AL3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 TERMINAL 2.5-2.5 MMA AWG 14-L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- TERMINAL 25-25 MMA AWG 3, FACTORY SET : CONSTANT TORQUE-SENSORLESS FLUX VECTOR CONTROL WITH PWM TYPE MOTOR CONTROL SIGNAL, FREQUENCY PI REGULATOR, INPUT PHASE BREAKS DRIVE-LINE SUPPLY OVERVOLTAGE AND UNDERVOLTAGE SAFETY CIRCUITS DRIVE-LINE SUPPLY PHASE LOSS SAFETY FUNCTION, FOR THREE PHASES SUPPLY DRIVE-MOTOR PHASE BREAKS DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH (ON POWER UP ONLY) DRIVE-OVERHEATING PROTECTION DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-THERMAL PROTECTION MOTOR, INTERNAL SUPPLY FOR LOGIC INPUTS 19...30 V 100 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (2.2 TO 10 KOHM) 10...10.8 V 10 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION
  • Speed Rating ALTIVAR 312
  • Standard 1 GN 13-150 HZ)EN/IEC 60068-2-6-1.5 MM 3-13 HZ)EN/IEC 60068-2-6, 1.2/50 AS - 8/20 AS SURGE IMMUNITY TEST LEVEL 3 IEC 61000-4-5-ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST LEVEL 4 IEC 61000-4-4-ELECTROSTATIC DISCHARGE IMMUNITY TEST LEVEL 3 IEC 61000-4-2-RADIATED RADIO-FREQUENCY ELECTROMAGNETIC FIELD IMMUNITY TEST LEVEL 3 IEC 61000-4-3, 15 GN 11 MS EN/IEC 60068-2-27, CE, IEC 61800-5-1-IEC 61800-3, IP20 ON UPPER PART WITHOUT COVER PLATE-IP21 ON CONNECTION TERMINALS-IP31 ON UPPER PART-IP41 ON UPPER PART, UL-CSA-NOM-C-TICK-GOST-DNV
  • Sub-Brand ALTIVAR 312
  • Type VARIABLE SPEED DRIVE
  • Voltage Rating 380/500VAC
  • Wattage 11KW
  • Width 12.0000
  • Width UOM IN

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items