Image is an illustration, may not reflect the exact product sold.


Other products by Schneider Electric

Schneider Electric - LTMR27PBD - Motor Management System, Profibus DP, 690V AC Operating Voltage, 1.35 to 27A Current Range

  • MFR SKU: LTMR27PBD
  • ITEM #: 16952998
  • 0 Reviews / 0 Questions
$1,192.60
Stock Status: SHIPS SOON (reserve your unit today)

ITEM #: 16952998
Motor Management System, Profibus DP, 690V AC Operating Voltage, 1.35 to 27A Current Range
This listing is for each.

Schneider Electric - LTMR27PBD - Motor Management System, Profibus DP, 690V AC Operating Voltage, 1.35 to 27A Current Range

  • Item #: 16952998
  • MFR SKU: LTMR27PBD
  • Amperage Rating 1.3527A
  • Application Equipment monitoring and control
  • Approximate Weight 1.170
  • Brand TeSys
  • Catalog Number LTMR27PBD
  • Connection CONTROL CIRCUIT CONNECTOR 1 0.25-2.5 MMA AWG 24...AWG 14)FLEXIBLE WITH CABLE END-CONTROL CIRCUIT CONNECTOR 1 0.2-2.5 MMA AWG 24...AWG 14)FLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT CONNECTOR 1 0.25-2.5 MMA AWG 24...AWG 14)FLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT CONNECTOR 1 0.2-2.5 MMA AWG 24...AWG 14)SOLID WITHOUT CABLE END-CONTROL CIRCUIT CONNECTOR 2 0.2-1 MMA AWG 24...AWG 14)FLEXIBLE WITH CABLE END-CONTROL CIRCUIT CONNECTOR 2 0.2-1.5 MMA AWG 24...AWG 14)FLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT CONNECTOR 2 0.5-1.5 MMA AWG 24...AWG 14)FLEXIBLE WITHOUT CABLE END-CONTROL CIRCUIT CONNECTOR 2 0.2-1 MMA AWG 24...AWG 14)SOLID WITHOUT CABLE END
  • Country of Origin CHN
  • Manufacturer Schneider Electric
  • Operating Cycles 1800 CYC/H
  • Operating Temperature -20-60 AC
  • Size 4.82
  • Special Features Starting current and time; Fault recording; Remaining operating time before overload tripping; Motor control command recording; Running hours counter/operating time; Trip context information; Trip history information; Phase fault and earth fault trip counters; Event recording; Waiting time after overload tripping; Web server
  • Standard 650 AC EN/IEC 60695-2-12-960 AC UL 94, C-TICK-CCC-ABS-NOM-LROS (LLOYDS REGISTER OF SHIPPING)-EAC-RINA-ATEX-GL-KERI-DNV-UL-CSA-RMROS-BV, IP20, UL 508-IACS E10-EN 60947-4-1-IEC 60947-4-1-CSA C22.2 NO 14, ELECTROSTATIC DISCHARGE, 3 8 KV AIR, 6 KV CONTACT)EN/IEC 61000-4-2-SURGES 1 KV)EN/IEC 61000-4-5-SURGES 2 KV)EN/IEC 61000-4-5-SURGES 2 KV)EN/IEC 61000-4-5-SURGES 4 KV)EN/IEC 61000-4-5-RADIATED RF FIELDS, 3 10 V/M)EN/IEC 61000-4-3-FAST TRANSIENTS IMMUNITY TEST, LEVEL 3 2 KV)EN/IEC 61000-4-4-FAST TRANSIENTS IMMUNITY TEST, LEVEL 4 4 KV)EN/IEC 61000-4-4-VOLTAGE DIPS AND INTERRUPTIONS IMMUNITY TEST 70 , 500 MS)EN/IEC 61000-4-11-CONDUCTED RF DISTURBANCES 10 V)EN/IEC 61000-4-6-SURGES 0.5 KV)EN/IEC 61000-4-5-SURGES 1 KV)EN/IEC 61000-4-5-SURGES 1 KV)EN/IEC 61000-4-5, VIBRATIONS MOUNTED ON SYMMETRICAL RAIL1 GN, 5...300 HZ EN/IEC 60068-2-6-VIBRATIONS PLATE MOUNTED4 GN, 5...300 HZ EN/IEC 60068-2-6-SHOCKS HALF SINE WAVE ACCELERATION15 GN FOR 11 MS EN/IEC 60068-2-27
  • Stock Status NONSTOCK
  • Trade Size 4.82
  • Type Motor controller
  • Voltage 24 V DC
  • Wattage 480 VA AC-15), IE = 2 A, 500000 CYCLES OUTPUT)-30 W DC-13), IE = 1.25 A, 500000 CYCLES OUTPUT)

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items