SE International - MC1K - Radiation Alert MC1K Radiography Detector, Energy-Compensated; 0-1000 Mr/Hr

  • MFR SKU: MC1K
  • ITEM #: 3421834
  • 0 Reviews / 0 Questions
Lists At: $959.59 You Save: $92.46
9.64 % OFF
$867.13
Stock Status: SHIPS SOON (reserve your unit today)

ITEM #: 3421834
Easy to use detector ensures safety Precision sensitivity provides accurate readings Easy setup and readability All models are factory-calibrated to pulse generator and can be calibrated to ANSI standards by any certified lab. Anti-saturation circuit is good to at least 100 times the maximum reading in the highest range. No special probes are required. Ergonomic design decreases workers fatigue over long periods of use. Meters operate on one 9 V battery (sold separately). Radiography Detector has...
ITEM #: 3421834
Easy to use detector ensures safety Precision sensitivity provides accurate readings Easy setup and readability All models are factory-calibrated to pulse generator and can be calibrated to ANSI standards by any certified lab. Anti-saturation circuit is good to at least 100 times the maximum reading in the highest range. No special probes are required. Ergonomic design decreases workers fatigue over long periods of use. Meters operate on one 9 V battery (sold separately). Radiography Detector has a wide range with four range multipliers (x1, x10, x100, and x1000). Compensated sensor provides increased sensitivity to low-level gamma and X-ray emissionsdetects background levels as low as 5 cpm. carrying case with belt clip This listing is for Each.
Read More >>

SE International - MC1K - Radiation Alert MC1K Radiography Detector, Energy-Compensated; 0-1000 Mr/Hr

  • Item #: 3421834
  • MFR SKU: MC1K
  • Range: 0 to 50 mR/hr; 0 to 50, 000 cpm or 0 to 500 mSv/hr Accuracy: 15% of reading (referenced to Cs-137), typical Detector: Geiger-Mller (GM) tube, 9 mm dia Function: Audible/visible counter Sensitivity: 415 cpm/mR/hr Source: Cs-137 Display: Analog bar graph Output: 3.5 mm headphone jack with pulse out Window: Mica Window Density: 1.5 to 2.0 mg/cm².
  • Background (cpm): 10 to 20 Battery: One 9 V Depth (in): 1
  • Width (in): 8 1/4
  • Height (in): 2 3/4
  • Description: Radiography Detector, Energy-Compensated; 0-1000 Mr/Hr