Image is an illustration, may not reflect the exact product sold.


Other products by WTW

WTW - 600325 - WTW Turb 430 T-Portable; (90 tungsten) acc. US EPA 180.1 incl. cal. std kit (0.02-10-1000 NTU) and accessories 2 empty cuvette (28m), cleaning tissues, batt.; suitable for drinking water. Optional LabStation LS Flex /430 with software

  • MFR SKU: 600325
  • ITEM #: 12480095
  • 0 Reviews / 0 Questions
$3,632.63
  • Saw It For Less?
Stock Status: SHIPS SOON(reserve your unit today)

ITEM #: 12480095
Nephelometric or transmittance measuring - The nephelometric measurement at 90° scattered light is advantageous for lower turbidity, whereas the transmission measurement at 180° is beneficial for medium to high turbidity values: With increasing turbidity, restray and scattering effects between particles are growing bigger. The reduction of light intensity in this case leads to a more accurate result than a 90° nephelometric measurement. Therefore, lab meters for high values are equipped...
ITEM #: 12480095
Nephelometric or transmittance measuring - The nephelometric measurement at 90° scattered light is advantageous for lower turbidity, whereas the transmission measurement at 180° is beneficial for medium to high turbidity values: With increasing turbidity, restray and scattering effects between particles are growing bigger. The reduction of light intensity in this case leads to a more accurate result than a 90° nephelometric measurement. Therefore, lab meters for high values are equipped with several measuring options: Ratio modes calculate the final result from different measured angles. For ratiometric measurements, there is no specific standard method to be followed; rather, procedures are established by the application or industry.
White light has a higher sensitivity for small particles, however, the inherent coloration of the solution has a stronger disturbing effect in this case. The IR measurement is required by DIN ISO, the white light measuring by US EPA.
WTW Turb 430 T-Portable; (90° tungsten) acc. US EPA 180.1 incl. cal. std kit (0.02-10-1000 NTU) and accessories 2 empty cuvette (28m), cleaning tissues, batt.; suitable for drinking water. Optional LabStation LS Flex /430 with software package for GLP compliant data export
This listing is for Each
Read More >>

WTW - 600325 - WTW Turb 430 T-Portable; (90 tungsten) acc. US EPA 180.1 incl. cal. std kit (0.02-10-1000 NTU) and accessories 2 empty cuvette (28m), cleaning tissues, batt.; suitable for drinking water. Optional LabStation LS Flex /430 with software

  • Item #: 12480095
  • MFR SKU: 600325

There are no questions about this product yet. Be the first to ask a question.

0 out of 5 stars
5 Star
0 %
4 Star
0 %
3 Star
0 %
2 Star
0 %
1 Star
0 %

Review this product

Tell us about your personal experience

Recently Viewed Items